Row of labelled reagent sample bottles
QL256-1 · reagent form
Solvent extraction plant interior
Circuit context
Oil and water phase interface in a separation funnel
Liquid phases
QL256-1CAS on requestSample on request
NiCo

QL256-1 extractant

Nickel-cobalt co-extraction extractant

CAS on request

QL256-1 co-extracts nickel and cobalt from clarified sulphate liquors so the pair leaves the circuit in one strip liquor. At 25% v/v dilution the loading capacity exceeds 10 g/L and the residual nickel and cobalt in the raffinate stay below 0.02 g/L, which suits spent ternary battery leachates and laterite liquors where the two metals are wanted together.

  • ≥97.0% active content
  • ≥10 g/L capacity at 25% v/v
  • Raffinate below 0.02 g/L
  • Water below 0.1%

Key parameters

Values are confirmed on the technical data sheet issued with the quotation.

Appearance
Colourless to pale yellow liquid
Active content
≥97.0%
Density (25 °C)
0.87–0.88 g/cm³
Dynamic viscosity (25 °C)
<50 cP
Flash point (closed cup)
140 °C
Freezing point
≤10 °C
Water content
<0.1%
Ni/Co saturation capacity (25% v/v)
≥10 g/L
Raffinate Ni + Co
<0.02 g/L
Phase separation
≤2.0 min
Entrained solvent, raffinate
≤50 ppm
Entrained solvent, strip liquor
≤20 ppm

Typical use

Co-extraction of nickel and cobalt from spent ternary battery leach liquor, laterite nickel hydrometallurgy, and high-concentration nickel-cobalt residues or wastewater.

  • 01Feed ratio stability matters more than total tenor; upstream blending is confirmed before the stage is sized.
  • 02Manganese and magnesium behaviour is checked on the sample rather than assumed from the datasheet.
  • 03Phase separation of 2 minutes or less is maintained with the diluent and modifier stated in the test report.

Packing and storage

  • 01200 kg plastic drum
  • 021000 L IBC tank

Pack sizes are confirmed with the quotation. Mixed pallets and customer-specified packing are quoted on request.

Sealed chemical drums stored in a warehouse aisle
Warehouse storage · sealed containers
  • Store in a cool, dry and ventilated warehouse.
  • Keep away from direct sunlight, open flame and strong oxidisers.
  • Keep containers sealed and do not store with alkaline products.

Enquire about QL256-1

Reagent recommendations are issued against the feed data you share.